| Model |
|
Description | ||||||||||
![]() AD375MA - AD375MAL |
![]() |
![]() |
![]() |
![]() |
![]() |
The Shaft Encoder Model AD375MA is suitable for measuring water level in wells and dams. |
![]() GCO1-P |
![]() |
![]() |
![]() |
![]() |
![]() |
The GCO1-P is used in conjunction with a bubbler system. It permits the use of extremely low bubble rates with increased accuracy and near total reduction of lag between actual level rise and orifice pressure. |
![]() GPF and GPR |
![]() |
![]() |
![]() |
![]() |
![]() |
The Staff Gauge Plates are primarily used to measure the depth of streams or rivers. |
![]() HS23 |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS23 Bubble Unit is the most economical and reliable depth sensing system. It consists of a bubbler with the gas line leading back to a pressure sensing instrument located in a central or more accessible area. |
![]() HS-30 |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS-30 when used in conjunction with the GCO1, it forms a complete Hydrostatic Level Sensor for measuring water level in dams, rivers, canals and tanks with up to 30 mH2O (100 ft). |
![]() HS35 |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS-35, when used with a Dry Nitrogen source and the Gas Chamber Orifice GC01, forms a complete Hydrostatic Level Sensor for measuring water level in dams, rivers, canals and tanks with up to 300m (900ft) of river line and 30m (100ft) of water head. The unit can be used with any pressure transducer. |
![]() HS-40 |
![]() |
![]() |
![]() |
![]() |
![]() |
The Advanced Bubbler System Model HS-40 has been designed to replace conventional nitrogen gas bottle supply to bubble units/gas purge systems for measuring water level in dams, rivers, canals and tanks with up to 30 mH2O (100 ft). |
![]() HS-40WLS |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS40/WLS Compact Water Level System has been designed to replace a conventional nitrogen gas bottle supply for accurate and reliable measurement of water level in dams, rivers, canals and tanks to a maximum water head of 30m H2O (100 ft)
|
![]() HS-45 |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS-45 Gas Purge Compressors have been designed to replace the conventional nitrogen gas bottle supply to bubble units/gas purge systems for water level measurement. |
![]() HS-55 |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS-55 Gas Purge Compressors have been designed to replace the conventional nitrogen gas bottle supply to bubble units/gas purge systems for water level measurement. |
![]() HS-55DB |
![]() |
![]() |
![]() |
![]() |
![]() |
The HS-55DB Gas Purge Compressors have been designed to replace the conventional nitrogen gas The Model HS-55DB is used in a situation where a site needs two orifices operating simultaneously |
![]() HS-55DO |
![]() |
![]() |
![]() |
![]() |
![]() |
The Model HS-55DO Gas Purge Compressors is used in a situation where a site needs two orifices at two different levels. Note one orifice can operated at the time while the other orifice is shut. |
![]() IC1 |
![]() |
![]() |
![]() |
![]() |
![]() |
The IrComms Model IC1 when used in conjunction with Hydrological Services data loggers, the user is able to configure the logger settings and download the data stored in the logger using an Infrared compatible PDA or Laptop. |
![]() iCE3 |
![]() |
![]() |
![]() |
![]() |
![]() |
The iCE3 has been designed and constructed as a compact, intelligent unit to access legacy RS232 equipment through a wireless IP network. It can manage either a permanent link (on private/static networks) or a scheduled connection regime (on public/dynamic networks). |
![]() iRIS150 |
![]() |
![]() |
![]() |
![]() |
![]() |
The iRIS 150 Data Logger is a water-proof, self-powered and compact, yet still featuring an LCD display and keypad. It can be connected to a wide variety of sensors, and features two analogue (0-5V, 0-20mA) inputs, two digital inputs, limited SDI-12 serial instrument support and a single digital output for alarm or control purposes. |
![]() iRIS350 |
![]() |
![]() |
![]() |
![]() |
![]() |
The iRIS 350 Data Logger is constructed for use in harsh outdoor and industrial environments. It is compact, cost effective and easily configured, with support for a wide range of instrumentation: There are four physical communication interfaces RS232, GSM/GPRS or HSDPA (Next G) or CDMA-1X modem, SDI-12 Serial Instrumentation, Serial Camera. |
![]() KLL |
![]() |
![]() |
![]() |
![]() |
![]() |
The Electric Contact Meter Model KLL is a portable reliable instrument for measuring the water level and total depth in boreholes, wells and reservoirs. |
![]() ML4-20 |
![]() |
![]() |
![]() |
![]() |
![]() |
The MiniLog Model ML4-20, 4-20mA Data Acquisition system is a compact, programmable acquisition device used for remote data logging application e.g. Water level measurement via 4-20mA interface of the AD375A, WL1100, WL3100 or similar. |
![]() PS9800 |
![]() |
![]() |
![]() |
![]() |
![]() |
The PS9800 is a Submersible Pressure transmitter, with optional temperature channel. It has industry standard, 2-wire, 4-20 mA configuration with reading that can be absolute, gauge, or sealed gauge. The PS9800 features are thermally compensated, typical accuracy of ± 0.06% FSO, low power consumption (9-24 VDC), small diameter 19mm (0.75") , 316 SS, Viton, Teflon construction (titanium optional), reverse polarity protection, under- and over- current limitation, built-in transient protection, thermally stable with 2% over 50 degrees standard and 0.2% over 40 degrees with enhanced calibration option . |
![]() PS98i |
![]() |
![]() |
![]() |
![]() |
![]() |
The PS98i is a Submersible Pressure transmitter, with optional temperature channel. It has industry standard, 2-wire, 4-20 mA configuration with reading that can be absolute, gauge, or sealed gauge. The PS98i features are typical accuracy of ± 0.1% FSO, low power consumption (9-24 VDC), small diameter 19mm (0.75") , 316 SS, Viton, Teflon construction (titanium optional), reverse polarity protection, under- and over- current limitation, built-in transient protection . |
![]() PT12 |
![]() |
![]() |
![]() |
![]() |
![]() |
The PT12/SDI-12 submersible pressure sensor represents the latest in state-of-the-art level measurement technology. Building on years of successful experience, this industry standard SDI-12 v1.3 interface device offers great noise immunity, thermal performance and transient protection. In addition, this device returns temperature and time data and operates with low power. The sensor end cone is interchangeable with a 1/4” NPT inlet which allows for increased application use and easy hookup. The modular-designed PT12/SDI-12 sensor can be factory serviced and repaired saving on future upgrade and repair costs. |
![]() PT2X |
![]() |
![]() |
![]() |
![]() |
![]() |
The PT2X is a Submersible Pressure, Temperature and time sensor. It has a Modbus or SDI-12 interface for greater flexibility. The sensor reading can be absolute, gauge, or sealed gauge. The PT2X features are typical accuracy of ± 0.06% FSO, low power consumption internal AA batteries or optional options (12 VDC) with AA’s acting as backup,data logging capability, Wireless connectivity – radios and/or cellular,RS485 network – allows several sensors to be networked together and allows much longer cable leads than does RS232. |
![]() RQ-30 |
![]() |
![]() |
![]() |
![]() |
![]() |
The RQ-30 radar sensor measures the stage and the flow velocity and can be used to produce discharge records at stations where conventional methods cannot be used. Furthermore it allows to directly calculate the discharge in the sensor. Two techniques of contact free radar measurement are combined in one system. |
![]() WDC100 |
![]() |
![]() |
![]() |
![]() |
![]() |
The "Outpost" Wireless Data Collection is a Transmit/Receive device that has been designed to measure water level in lakes, dams and seas. Each Outpost "Tx" can be connected to 1x Analogue (4-20mA) sensor, 1x Digital sensor and up to 9 SDI-12 transducers or parameters. |
![]() WDC100B |
![]() |
![]() |
![]() |
![]() |
![]() |
The "Outpost" Wireless Data Collection is a Transmit/Receive device that has been designed to measure water level in lakes, dams and seas. Each Outpost "Tx" can be connected to 1x Analogue (4-20mA) sensor, 1x Digital sensor and up to 9 SDI-12 transducers or parameters. |
![]() WINCOMLOG |
![]() |
![]() |
![]() |
![]() |
![]() |
WinComLog is a Windows Application used to communicate with a Hydrological Services RRDL3 Logger, RDL4 Logger, ML1 Logger, ML420 Logger or a Data Retrieval unit via the RS232 port. The application has 4 distinct screens that allow terminal type communication (with data capture), as well as plotting of Rain and River data, Scheduling of automatic data collection and upgrading new firmware into the Logger. |
![]() WL2100D |
![]() |
![]() |
![]() |
![]() |
![]() |
The WL2100D dry pressure transducers allows the measurement of water head to a fine degree of accuracy and repeatability, due to full temperature compensation, and interfaces via SDI-12 or 4-20mA. |
![]() WL3100/WL3100A |
![]() |
![]() |
![]() |
![]() |
![]() |
The WL 3100 and WL3100A are dry pressure transducers. The SDI-12 or RS232 outputs allows multiple connection to a single data logging recorder, transmitting at 1200 baud over distance up to 60 metres (200 ft). |
![]() WLT420 |
![]() |
![]() |
![]() |
![]() |
![]() |
The Wireless Level Transmitter’s primary purpose is to periodically measure a 4-20mA transducer, and to wirelessly transmit the measurement to a different location and reproduce the 4-20mA signal. |
Hydrological Services Pty Ltd Address: 48-50 Scrivener Street Warwick Farm, NSW, Australia, 2170 |
Contact Details: Ph: +612 9601 2022 Fax: +612 9602 6971 Email Us |
|
Hydrological Services Pty Ltd preserves the right to modify this website at any time without notice |